REGO Miscellaneous Equipment (including Rotogages & ESVs)
Brass Float Gauges
Float Gauges are designed to provide an accurate determination of LP-Gas contain contents. These gauges top mount in either a standard 1 1/4″ F. NPT threaded coupling or a junior top mount flanged coupling. Feature easy to read Junior dial with a 5 % to 90% reading.
Float Gauges are designed to provide an accurate determination of LP-Gas contain contents. These gauges top mount in either a standard 1 1/4″ F. NPT threaded coupling or a junior top mount flanged coupling. Feature easy to read Junior dial with a 5 % to 90% reading.
Part Number | Container Connection | For use with Container Size | |
Diameter | Gallons | ||
JT2400B4 | Junior Flange 4 Bolt | 24″ | 120 |
JT3000B4 | Junior Flange 4 Bolt | 30″ | 250/320 |
JT3700B4 | Junior Flange 4 Bolt | 37″ | 500 |
JT4100B4 | Junior Flange 4 Bolt | 41″ | 1,000 |
JT2400T125 | Threaded 1 1/4″ M. NPT | 24″ | 120 |
JT3000T125 | Threaded 1 1/4″ M. NPT | 30″ | 250/230 |
JT3700T125 | Threaded 1 1/4″ M. NPT | 37″ | 500 |
JT4100T125 | Threaded 1 1/4″ M. NPT | 41″ | 1,000 |
Needle Valves
These valves are high quality, “true” throttling valves. Unlike most so- called needle valves, both the body seat and stem are tapered to provide fine, precise control over a wide range of adjustment without stem galling.
The 1224 may be used as a small, inexpensive shut-off valve between a pressure gauge and bulk storage container to allow for convenient gauge replacement.
The 1314, 1316 and 1318 provide taper pipe thread by left hand hose connection threads and are useful in a wide range of torch and fuel burn- er applications where an accurate throttling action is required.
Part Number | Inlet Connection | Outlet Connection | Height | Length |
1224WA | 1/4″ M. NPT | 1/4″ M. NPT | 1 9/16″ | 1 3/4″ |
1314WA | 9/16″ – 18 L.H. | 1/8″ M. NPT | 1 9/16″ | 1 3/4″ |
1316WA | 9/16″ – 18 L.H. | 1/4″ M. NPT | 1 9/16″ | 1 3/4″ |
1318WA | 1/4″ M. NPT | 9/16″ – 18 L.H. | 1 9/16″ | 1 3/4″ |
Household Gas Detector/Alarm
The 100-HGD gas fume detection/alarm unit gives advance warning of gas leaks well below the hazard level (1/4th the lowest explosive level). It provides the homeowner more time to take action to protect the family and remedy the problem.
Part Number | Description |
100-HGD | Household Propane Gas Alarm |
Semi-Internal “Pop-Action” Pressure Relief Valves for Large Storage Containers
Designed especially for use as a primary relief valve on large stationary storage containers, these low profile relief valves are generally mounted in half couplings. However, they are designed so that the inlet ports clear the bottom of a full 2″ coupling. This assures that the relief valve should always be capable of maximum flow under emergency conditions.
Flow Capacity SCFM/Air* | Accessories | ||||||
Part Number | Start To Discharge Setting PSIG | Container Connection M.NPT | UL (At 120% of Set Pressure) | ASME (At 120% of Set Pressure) | Suitable for Tanks w/Surface Area Up To:** | Protective Cap | Pipeaway Adapter |
7534B | 125 | 2″ | 6,025 | – | 319 Sq. Ft. | 7534-40 | 7534-20*** |
7534G | 250 | 2″ | 11,675 | 10,422 | 708 Sq. Ft. | 7534-40 | 7534-20*** |
* Flow rates shown are for bare relief valves. Adapters and pipaaways wil reduce flow as discussed in the forwording information.
** Per NFPA Pamphlet58, Appendix D. Area shown is for UL cr ASME – whicnever s larger.
*** 3″ F. NPT outlet connection.
External “Pop-Action” Pressure Relief Valves for ASME Containers and Bulk Plant Installations
Designed for use as a primary relief valve on ASME above ground and underground containers, bulk plant installations and skid tanks. The 3131 Series may also be used as a primary or secondary relief valve on DOT cylinders, or as a hydrostatic relief valve. All working components of these relief valves are outside the container connection, so the valves must be protected from physical damage.
Accessories | |||||||||||
Flow Capacity SCFM/Air (a) | Pipeaway Adapter | ||||||||||
Part Number | Start To Discharge Setting PSIG | Container Connection M. NPT | Overall Height (Approx.) | Wrench Hex Section | UL (At 120% of Set Pressure) | ASME (At 120% of Set Pressure) | Suitable for Tanks with Surface Area Up To: (e) Sq. Ft. | Protective Cap | Part Number | Outlet Size | Weep Hole Deflector |
AA3126L030 | 30 | 1/2″ | 2 3/8″ | 7/8″ | (b) | – | – | 7545-40 | AA3126-10 | 1/2″ M. NPT | – |
A3149L050 | 50 | 2 1/2″ | 10 1/2″ | 4 1/8″ | 2600 (c) | – | 113 | 3149-40 | (h) | (h) | Included (j) |
A3149L200 | 200 | 2 1/2″ | 10 1/2″ | 4 1/8″ | 8770 (c) | – | 500 | 3149-40 | AA3126-10 | 1/2″ M. NPT | Included (j) |
AA3126L250 | 250 | 1/2″ | 2 3/8″ | 7/8″ | 277 (c) | – | 23 (f) | 7545-40 | – | – | – |
3131G | 250 | 3/4″ | 3 7/16″ | 1 3/4″ | 2060 | 1939 | 85 | 3131-40 (g) | AA3131-10 | 1″ F. NPT | – |
AA3130UA250 | 250 | 3/4″ | 3 7/16″ | 1 3/4″ | 2045 | 1838 | 249 (f) | AA3130-40P | – | – | – |
W3132G | 250 | 1″ | 3 1/32″ | 2 3/8″ | 3340 | – | 154 | 3132-54 (g) | 3132-10 | 1 1/4″ F NPT | 3133-11 |
3132G | 250 | 1 1/4″ | 3 1/32″ | 2 3/8″ | 4130 | – | 200 | 3132-54 (g) | – | – | 3133-11 |
T3132G | 250 | 1 1/4″ | 3 1/32″ | 2 3/8″ | 3790 | – | 180 | 3132-54 (g) | 3132-10 | 1 1/4″ F. NPT | 3133-11 |
MV3132G | 250 | 1 1/4″ | 3 1/32″ | 2 3/8″ | 3995 | – | 190 | 3132-54 (g) | – | – | 3133-11 |
3135G | 250 | 1 1/4″ | 5 21/32″ | 2 11/16″ | 5770 | – | 300 | 3135-54 (g) | 3135-10 | 2″ F. NPT | 3133-11 |
AA3135UA250 | 250 | 1 1/4″ | 6 13/32″ | 2 11/16″ | 6430 | 5080 (d) | 1010 (f) | AA3135-40PR | AA3135-10 | 2″ F. NPT | 3133-11 |
3133G | 250 | 1 1/2″ | 5 15/16″ | 3 1/8″ | 6080 | – | 320 | 3133-40 (g) | 3133-10 | 2″ F. NPT | 3133-11 |
A3149G | 250 | 2 1/2″ | 10 1/2″ | 4 1/8″ | 10390 | 9153 | 612 | 3149-40 | (h) | (h) | Included (j) |
AA3130UA265 | 3/4″ | 3 7/16″ | 1 3/4″ | 2125 | 1912 | 261 (f) | AA3130-40P | AA3131-10 | 1″ F. NPT | – | |
AA3135UA265 | 265 | 1 1/4″ | 6 13/32″ | 2 11/16″ | 6615 | 5370 (d) | 1045 (f) | AA3135-40PR | AA3135-10 | 2″ F. NPT | 3133-11 |
AA3126L312 | 312 | 1/2 | 2 3/8″ | 7/8″ | 330 (c) | – | 27 (f) | 7545-40 | AA3126-10 | 1/2″ M. NPT | – |
(a) Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow as discussed in forewording information.
(b) Not UL or ASME rated. .059 square inch effective area.
(c) Not UL or ASME rated. EC110 rated at 120%of set pressure.
(d) Rated at 110%of set pressure.
(e) Per NFPA Pamphlet#58, Appendix D. Area shown is for UL or ASME flow rating-whichever is larger.
(f) Per ANSI K61.1-1972, Appendix A.
(g) Cap supplied with chain.
(h) Outlet 3 1/2-8N (F) thread, will accept 3″ M. NPT pipe thread.
(i) Weep hole deflector is Part No. A3134-11B.